DSP Firmware Update:
- Flex-8DL version 1.17: fixed issue where Dirac Delay value is always shown as 19.97ms.

Improvements / New Features
- SHD-Studio and SHD-Power now has their own dedicated User Manual pages
- Open-Source-Licenses used in the Device Console now included in the About Page
- Software Updates:
* Firmware-only update mechanism added. User will be prompt with a dialog with the message 'Newer Version of Firmware(s) used in your devices is Available. Download and Install?'.
Note-1: This in-app-update only updates the firmware(s) bundled in the application itself. User will still need to program the new firmware to device itself by following the existing methods.
Note-2: Only previously connected devices will be affected. For example, if Device Console has never been connected to a 2x4HD, any 2x4HD-specific firmware updates will not notify the user.
Note-3: The checking follows general Software Update checking schedule. In particular, there will be no checking for in-app-updates if Software Update checking is disabled.
* A 'Check-Now' button is added to allow user to check for Software Updates outside the scheduled periods.
* Software-Update-Check related failures will now longer pop up a dialog, in case the DC is working in environment without internet access.
* The two-minute check at start up is removed, now that Check-Now button is available.
* On the other hand, Check-Now action, initiated by user, will always shows a dialog reporting results: Available, Already-Up-To-Date or Errors.
- Dialogs has been increased at MaCOS version to better display the messages, especially the 'Settings Changed' action-prompt upon connection.
- EULA license agreement dialog GUI buttons colors.

Bug Fixes
- Dirac-License-Email: improve the 'mailto' link hoping to prevent incorrect activation code being added to the Email Compose Window.
- Dirac calibration: fixed problem where changes made with remote-control not being reflected to the Device Console, immediately after Dirac Calibration.
- Dirac calibration: fixed problem where in some cases, the first trigger of audio-source change from Device Console will have no effect, immediately after Dirac Calibration.
- Level Meter: fixed problem where Level Meter will not update values right after Preset is changed with remote-control or front-panel-knob

NOTE: SHD/DDRC24/2x4HD are in template/Offline support ONLY. i.e. you will not be able to connect/control any of these platforms yet. We plan to release support in the comming weeks once the software QC is finalized for these platforms.